{"id":43753,"date":"2020-07-08T09:00:39","date_gmt":"2020-07-08T07:00:39","guid":{"rendered":"https:\/\/nolabnoparty.com\/?p=43753"},"modified":"2020-07-08T10:47:23","modified_gmt":"2020-07-08T08:47:23","slug":"dell-emc-unity-software-upgrade","status":"publish","type":"post","link":"https:\/\/nolabnoparty.com\/en\/dell-emc-unity-software-upgrade\/","title":{"rendered":"Dell-EMC Unity software upgrade"},"content":{"rendered":"<p><img decoding=\"async\" class=\"aligncenter wp-image-44537 size-full\" title=\"dell-unity-software-upgrade-01\" src=\"https:\/\/nolabnoparty.com\/wp-content\/uploads\/2020\/06\/dell-unity-software-upgrade-01.jpg\" alt=\"dell-unity-software-upgrade-01\" width=\"602\" height=\"202\" \/><\/p>\n<p>To keep storage performance at the highest level and to prevent potential issues, the <a href=\"https:\/\/nolabnoparty.com\/en\/dell-emc-data-domain-ve-os-upgrade\/\">Dell-EMC<\/a> Unity storage software should be <strong>upgraded on regular basis<\/strong>.<\/p>\n<p>The upgrade procedure doesn't stop the storage functionality and can be safely performed <strong>during working hours<\/strong>. To avoid service disruption make sure to follow the right steps and <strong>recommended checks<\/strong>.<!--more--><\/p>\n<p>&nbsp;<\/p>\n<h2>Check installed software<\/h2>\n<p>The <strong>Unisphere web console<\/strong> is the tool used to manage the Unity storage device. Using your preferred browser, login to the console by entering the correct credentials.<\/p>\n<p><img decoding=\"async\" class=\"aligncenter wp-image-44539 size-large\" title=\"dell-unity-software-upgrade-02\" src=\"https:\/\/nolabnoparty.com\/wp-content\/uploads\/2020\/06\/dell-unity-software-upgrade-02-600x460.jpg\" alt=\"dell-unity-software-upgrade-02\" width=\"600\" height=\"460\" \/><\/p>\n<p>Before starting the upgrade procedure, you need to <strong>identify the current installed software<\/strong> in the Unity. Click the <strong>System Status icon<\/strong> to get current software version.<\/p>\n<p><img decoding=\"async\" class=\"aligncenter wp-image-44541 size-large\" title=\"dell-unity-software-upgrade-03\" src=\"https:\/\/nolabnoparty.com\/wp-content\/uploads\/2020\/06\/dell-unity-software-upgrade-03-600x220.jpg\" alt=\"dell-unity-software-upgrade-03\" width=\"600\" height=\"220\" \/><\/p>\n<p>Once the version has been identified, go to <a href=\"https:\/\/support.dell.com\" target=\"_blank\" rel=\"noopener noreferrer\">support.dell.com<\/a> website and download the latest available software. Generally you may also find the updated <strong>firmware for the installed drives<\/strong>. Download both and check the <strong>compatibility matrix<\/strong> to ensure a direct upgrade to the desired version is actually supported.<\/p>\n<p>&nbsp;<\/p>\n<h2>Reboot the Unity's storage processors<\/h2>\n<p>To verify if both <strong>controllers can be restarted<\/strong> with no issues, the controllers reboot is the first operation to do before the starting the upgrade.<\/p>\n<p>From the Unisphere GUI, access the <strong>Service<\/strong> area under <strong>SYSTEM<\/strong> and go to <strong>Service Tas<span style=\"color: #000000;\">ks<\/span><\/strong><span style=\"color: #000000;\"> tab. The first <strong>Storage Processor<\/strong> to reboot should <strong>not be marked as Primary<\/strong>. S<\/span>elect <strong>Reboot<\/strong> for the corresponding controller (<strong>Storage Processor A<\/strong> in the example) and click <strong>Execute<\/strong>.<\/p>\n<p><img decoding=\"async\" class=\"aligncenter wp-image-44543 size-large\" title=\"dell-unity-software-upgrade-04\" src=\"https:\/\/nolabnoparty.com\/wp-content\/uploads\/2020\/06\/dell-unity-software-upgrade-04-600x421.jpg\" alt=\"dell-unity-software-upgrade-04\" width=\"600\" height=\"421\" \/><\/p>\n<p>Enter the <strong>Service Password<\/strong> and click <strong>OK<\/strong> to reboot.<\/p>\n<p><img decoding=\"async\" class=\"aligncenter wp-image-44545 size-full\" title=\"dell-unity-software-upgrade-05\" src=\"https:\/\/nolabnoparty.com\/wp-content\/uploads\/2020\/06\/dell-unity-software-upgrade-05.jpg\" alt=\"dell-unity-software-upgrade-05\" width=\"530\" height=\"323\" \/><\/p>\n<p>While rebooting, the <strong>Storage Processor A Status<\/strong> is reported as <strong>Degraded<\/strong>.<\/p>\n<p><img decoding=\"async\" class=\"aligncenter wp-image-44547 size-large\" title=\"dell-unity-software-upgrade-06\" src=\"https:\/\/nolabnoparty.com\/wp-content\/uploads\/2020\/06\/dell-unity-software-upgrade-06-600x334.jpg\" alt=\"dell-unity-software-upgrade-06\" width=\"600\" height=\"334\" \/><\/p>\n<p>When the Storage Processor A has been successfully rebooted, <strong>repeat same operation<\/strong> also for the other controller (<strong>Storage Processor B<\/strong> in the example).<\/p>\n<p><img decoding=\"async\" class=\"aligncenter wp-image-44549 size-large\" title=\"dell-unity-software-upgrade-07\" src=\"https:\/\/nolabnoparty.com\/wp-content\/uploads\/2020\/06\/dell-unity-software-upgrade-07-600x398.jpg\" alt=\"dell-unity-software-upgrade-07\" width=\"600\" height=\"398\" \/><\/p>\n<p>As occurred for the first Processor, also the <strong>Storage Processor B Status<\/strong>\u00a0is reported as\u00a0<strong>Degraded<\/strong> during the reboot. Note that also the Storage Processor A has the Status reported as Degraded.<\/p>\n<p><img decoding=\"async\" class=\"aligncenter wp-image-44551 size-full\" title=\"dell-unity-software-upgrade-08\" src=\"https:\/\/nolabnoparty.com\/wp-content\/uploads\/2020\/06\/dell-unity-software-upgrade-08.jpg\" alt=\"dell-unity-software-upgrade-08\" width=\"542\" height=\"484\" \/><\/p>\n<p>Wait until the reboot process completes before proceeding with the upgrade.<\/p>\n<p>&nbsp;<\/p>\n<h2>Upgrade the software<\/h2>\n<p>Access the <strong>Settings<\/strong> area and go to <strong>Software Upgrades<\/strong> section. Before installing the new software, click <strong>Perform Health Checks<\/strong> button to ensure the storage can be safely upgraded.<\/p>\n<p><img decoding=\"async\" class=\"aligncenter wp-image-44553 size-large\" title=\"dell-unity-software-upgrade-09\" src=\"https:\/\/nolabnoparty.com\/wp-content\/uploads\/2020\/06\/dell-unity-software-upgrade-09-600x493.jpg\" alt=\"dell-unity-software-upgrade-09\" width=\"600\" height=\"493\" \/><\/p>\n<p>Click <strong>Perform Health Checks<\/strong>\u00a0to proceed.<\/p>\n<p><img decoding=\"async\" class=\"aligncenter wp-image-44555 size-large\" title=\"dell-unity-software-upgrade-10\" src=\"https:\/\/nolabnoparty.com\/wp-content\/uploads\/2020\/06\/dell-unity-software-upgrade-10-600x600.jpg\" alt=\"dell-unity-software-upgrade-10\" width=\"600\" height=\"600\" \/><\/p>\n<p>When the process has been completed with no errors, click <strong>Close<\/strong>.<\/p>\n<p><img decoding=\"async\" class=\"aligncenter wp-image-44557 size-large\" title=\"dell-unity-software-upgrade-11\" src=\"https:\/\/nolabnoparty.com\/wp-content\/uploads\/2020\/06\/dell-unity-software-upgrade-11-600x600.jpg\" alt=\"dell-unity-software-upgrade-11\" width=\"600\" height=\"600\" \/><\/p>\n<p>Now the storage can be safely upgraded. Click <strong>Start Upgrade<\/strong>.<\/p>\n<p><img decoding=\"async\" class=\"aligncenter wp-image-44559 size-large\" title=\"dell-unity-software-upgrade-12\" src=\"https:\/\/nolabnoparty.com\/wp-content\/uploads\/2020\/06\/dell-unity-software-upgrade-12-600x493.jpg\" alt=\"dell-unity-software-upgrade-12\" width=\"600\" height=\"493\" \/><\/p>\n<p>Click <strong>Next<\/strong>.<\/p>\n<p><img decoding=\"async\" class=\"aligncenter wp-image-44561 size-large\" title=\"dell-unity-software-upgrade-13\" src=\"https:\/\/nolabnoparty.com\/wp-content\/uploads\/2020\/06\/dell-unity-software-upgrade-13-600x486.jpg\" alt=\"dell-unity-software-upgrade-13\" width=\"600\" height=\"486\" \/><\/p>\n<p>Click <strong>Browse<\/strong> and select the previously downloaded software then click <strong>Next<\/strong>.<\/p>\n<p><img decoding=\"async\" class=\"aligncenter wp-image-44563 size-large\" title=\"dell-unity-software-upgrade-14\" src=\"https:\/\/nolabnoparty.com\/wp-content\/uploads\/2020\/06\/dell-unity-software-upgrade-14-600x486.jpg\" alt=\"dell-unity-software-upgrade-14\" width=\"600\" height=\"486\" \/><\/p>\n<p>The upgrade package is being uploaded to the system.<\/p>\n<p><img decoding=\"async\" class=\"aligncenter wp-image-44565 size-large\" title=\"dell-unity-software-upgrade-15\" src=\"https:\/\/nolabnoparty.com\/wp-content\/uploads\/2020\/06\/dell-unity-software-upgrade-15-600x486.jpg\" alt=\"dell-unity-software-upgrade-15\" width=\"600\" height=\"486\" \/><\/p>\n<p>Check the <strong>Automatically Reboot Storage Processors<\/strong> option in order to automatically reboot the controllers <strong>finalizing the upgrade<\/strong>.<\/p>\n<p><img decoding=\"async\" class=\"aligncenter wp-image-44567 size-large\" title=\"dell-unity-software-upgrade-16\" src=\"https:\/\/nolabnoparty.com\/wp-content\/uploads\/2020\/06\/dell-unity-software-upgrade-16-600x486.jpg\" alt=\"dell-unity-software-upgrade-16\" width=\"600\" height=\"486\" \/><\/p>\n<p>Click <strong>Finish<\/strong> to start the upgrade.<\/p>\n<p><img decoding=\"async\" class=\"aligncenter wp-image-44569 size-large\" title=\"dell-unity-software-upgrade-17\" src=\"https:\/\/nolabnoparty.com\/wp-content\/uploads\/2020\/06\/dell-unity-software-upgrade-17-600x486.jpg\" alt=\"dell-unity-software-upgrade-17\" width=\"600\" height=\"486\" \/><\/p>\n<p>The upgrade procedure begins. Take a break since the operation requires more than 1 hour.<\/p>\n<p><img decoding=\"async\" class=\"aligncenter wp-image-44571 size-large\" title=\"dell-unity-software-upgrade-18\" src=\"https:\/\/nolabnoparty.com\/wp-content\/uploads\/2020\/06\/dell-unity-software-upgrade-18-600x486.jpg\" alt=\"dell-unity-software-upgrade-18\" width=\"600\" height=\"486\" \/><\/p>\n<p>You may receive this error during the upgrade due to the <strong>reboot of the controller<\/strong> on which you are connected. Just click <strong>Reload<\/strong>.<\/p>\n<p><img decoding=\"async\" class=\"aligncenter wp-image-44573 size-full\" title=\"dell-unity-software-upgrade-19\" src=\"https:\/\/nolabnoparty.com\/wp-content\/uploads\/2020\/06\/dell-unity-software-upgrade-19.jpg\" alt=\"dell-unity-software-upgrade-19\" width=\"418\" height=\"266\" \/><\/p>\n<p>When the software upgrade process has been completed, click <strong>Reload Unisphere<\/strong> to load the upgraded content.<\/p>\n<p><img decoding=\"async\" class=\"aligncenter wp-image-44575 size-large\" title=\"dell-unity-software-upgrade-20\" src=\"https:\/\/nolabnoparty.com\/wp-content\/uploads\/2020\/06\/dell-unity-software-upgrade-20-600x486.jpg\" alt=\"dell-unity-software-upgrade-20\" width=\"600\" height=\"486\" \/><\/p>\n<p>The new version installation confirmation is displayed. Click <strong>Finish<\/strong>.<\/p>\n<p><img decoding=\"async\" class=\"aligncenter wp-image-44577 size-full\" title=\"dell-unity-software-upgrade-21\" src=\"https:\/\/nolabnoparty.com\/wp-content\/uploads\/2020\/06\/dell-unity-software-upgrade-21.jpg\" alt=\"dell-unity-software-upgrade-21\" width=\"468\" height=\"173\" \/><\/p>\n<p>&nbsp;<\/p>\n<h2>Upgrade the drive firmware<\/h2>\n<p>In addition to the software upgrade, you should also <strong>upgrade the drive firmare<\/strong>\u00a0if available.<\/p>\n<p>From <strong>Settings<\/strong>\u00a0area, access the <strong>Drive Firmware<\/strong> section and click <strong>Upgrade Drive Firmware<\/strong>. In the example the installed <strong>firmware version is ESF8<\/strong>.<\/p>\n<p><img decoding=\"async\" class=\"aligncenter wp-image-44579 size-large\" title=\"dell-unity-software-upgrade-22\" src=\"https:\/\/nolabnoparty.com\/wp-content\/uploads\/2020\/06\/dell-unity-software-upgrade-22-600x492.jpg\" alt=\"dell-unity-software-upgrade-22\" width=\"600\" height=\"492\" \/><\/p>\n<p>The <strong>Health Checks<\/strong> operation is performed to ensure disks can be upgraded with no issues.<\/p>\n<p><img decoding=\"async\" class=\"aligncenter wp-image-44581 size-large\" title=\"dell-unity-software-upgrade-23\" src=\"https:\/\/nolabnoparty.com\/wp-content\/uploads\/2020\/06\/dell-unity-software-upgrade-23-600x463.jpg\" alt=\"dell-unity-software-upgrade-23\" width=\"600\" height=\"463\" \/><\/p>\n<p>When the check completes successfully, click <strong>Next<\/strong>.<\/p>\n<p><img decoding=\"async\" class=\"aligncenter wp-image-44583 size-large\" title=\"dell-unity-software-upgrade-24\" src=\"https:\/\/nolabnoparty.com\/wp-content\/uploads\/2020\/06\/dell-unity-software-upgrade-24-600x463.jpg\" alt=\"dell-unity-software-upgrade-24\" width=\"600\" height=\"463\" \/><\/p>\n<p>Now click <strong>Browse<\/strong> and select the previously downloaded firmware package. Click <strong>Next<\/strong>.<\/p>\n<p><img decoding=\"async\" class=\"aligncenter wp-image-44585 size-large\" title=\"dell-unity-software-upgrade-25\" src=\"https:\/\/nolabnoparty.com\/wp-content\/uploads\/2020\/06\/dell-unity-software-upgrade-25-600x463.jpg\" alt=\"dell-unity-software-upgrade-25\" width=\"600\" height=\"463\" \/><\/p>\n<p>Click <strong>Finish<\/strong> to proceed with the drive firmware upgrade.<\/p>\n<p><img decoding=\"async\" class=\"aligncenter wp-image-44587 size-large\" title=\"dell-unity-software-upgrade-26\" src=\"https:\/\/nolabnoparty.com\/wp-content\/uploads\/2020\/06\/dell-unity-software-upgrade-26-600x463.jpg\" alt=\"dell-unity-software-upgrade-26\" width=\"600\" height=\"463\" \/><\/p>\n<p>The firmware is being applied to the drives installed in the Unity storage. It takes <strong>several minutes to complete<\/strong> depending on the number of installed disks in the storage.<\/p>\n<p><img decoding=\"async\" class=\"aligncenter wp-image-44589 size-large\" title=\"dell-unity-software-upgrade-27\" src=\"https:\/\/nolabnoparty.com\/wp-content\/uploads\/2020\/06\/dell-unity-software-upgrade-27-600x462.jpg\" alt=\"dell-unity-software-upgrade-27\" width=\"600\" height=\"462\" \/><\/p>\n<p>When the procedure completes successfully, click <strong>Close<\/strong> to exit the wizard.<\/p>\n<p><img decoding=\"async\" class=\"aligncenter wp-image-44591 size-large\" title=\"dell-unity-software-upgrade-28\" src=\"https:\/\/nolabnoparty.com\/wp-content\/uploads\/2020\/06\/dell-unity-software-upgrade-28-600x462.jpg\" alt=\"dell-unity-software-upgrade-28\" width=\"600\" height=\"462\" \/><\/p>\n<p>Checking the installed firmware version, the version has been <strong>upgraded to ESF9<\/strong>.<\/p>\n<p><img decoding=\"async\" class=\"aligncenter wp-image-44593 size-large\" title=\"dell-unity-software-upgrade-29\" src=\"https:\/\/nolabnoparty.com\/wp-content\/uploads\/2020\/06\/dell-unity-software-upgrade-29-600x493.jpg\" alt=\"dell-unity-software-upgrade-29\" width=\"600\" height=\"493\" \/><\/p>\n<p>The upgrade procedure is now complete and the Unity storage device can <strong>take benefit of latest features<\/strong> providing better performance and stability.<\/p>\n<p><img decoding=\"async\" title=\"signature\" src=\"https:\/\/nolabnoparty.com\/wp-content\/uploads\/images\/firma.jpg\" alt=\"signature\" \/><\/p>\n","protected":false},"excerpt":{"rendered":"<p>To keep storage performance at the highest level and to prevent potential issues, the Dell-EMC Unity storage software should be upgraded on regular basis. The upgrade procedure doesn't stop the storage functionality and can be safely performed during working hours. To avoid service disruption make sure to follow the right steps and recommended checks.<\/p>\n","protected":false},"author":3,"featured_media":44537,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"rop_custom_images_group":[],"rop_custom_messages_group":[],"rop_publish_now":"initial","rop_publish_now_accounts":{"linkedin_93tdZWzMZc_93tdZWzMZc":"","facebook_2879994398731222_17841400390232720":"","twitter_113568041_113568041":"","mastodon_115463926174894442_115463926174894442":""},"rop_publish_now_history":[],"rop_publish_now_status":"pending","footnotes":""},"categories":[903,2121],"tags":[2057,1958,2227,2213],"class_list":["post-43753","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-vmware-en","category-dell-emc-en","tag-dell","tag-emc","tag-software-en","tag-unity","has_thumb"],"_links":{"self":[{"href":"https:\/\/nolabnoparty.com\/en\/wp-json\/wp\/v2\/posts\/43753","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/nolabnoparty.com\/en\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/nolabnoparty.com\/en\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/nolabnoparty.com\/en\/wp-json\/wp\/v2\/users\/3"}],"replies":[{"embeddable":true,"href":"https:\/\/nolabnoparty.com\/en\/wp-json\/wp\/v2\/comments?post=43753"}],"version-history":[{"count":0,"href":"https:\/\/nolabnoparty.com\/en\/wp-json\/wp\/v2\/posts\/43753\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/nolabnoparty.com\/en\/wp-json\/wp\/v2\/media\/44537"}],"wp:attachment":[{"href":"https:\/\/nolabnoparty.com\/en\/wp-json\/wp\/v2\/media?parent=43753"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/nolabnoparty.com\/en\/wp-json\/wp\/v2\/categories?post=43753"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/nolabnoparty.com\/en\/wp-json\/wp\/v2\/tags?post=43753"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}