{"id":62212,"date":"2024-05-14T09:00:28","date_gmt":"2024-05-14T07:00:28","guid":{"rendered":"https:\/\/nolabnoparty.com\/?p=62212"},"modified":"2024-05-13T10:12:47","modified_gmt":"2024-05-13T08:12:47","slug":"vsan-8-esa-on-minisforum-ms-01","status":"publish","type":"post","link":"https:\/\/nolabnoparty.com\/en\/vsan-8-esa-on-minisforum-ms-01\/","title":{"rendered":"vSAN 8 ESA on Minisforum MS-01"},"content":{"rendered":"<p><img decoding=\"async\" class=\"aligncenter wp-image-62217 size-full\" title=\"vsan-8-esa-on-minisforum-ms-01-01\" src=\"https:\/\/nolabnoparty.com\/wp-content\/uploads\/2024\/05\/vsan-8-esa-on-minisforum-ms-01-01.jpg\" alt=\"vsan-8-esa-on-minisforum-ms-01-01\" width=\"602\" height=\"202\" \/><\/p>\n<p>To install the new <a href=\"https:\/\/core.vmware.com\/blog\/introduction-vsan-express-storage-architecture\" target=\"_blank\" rel=\"noopener\">vSAN 8 ESA<\/a> (Express Storage Architecture) on <a href=\"https:\/\/store.minisforum.com\/products\/minisforum-ms-01\" target=\"_blank\" rel=\"noopener\">Minisforum MS-01<\/a>, it is required to have <strong>NVMe disks only<\/strong> as internal storage in the hosts.<\/p>\n<p>Checking the hardware compatibility of Minisforum MS-01 used as hypervisor, prerequisites are not 100% met (it complains about NVMe disks) but <strong>enough to finalize the installation<\/strong>.<!--more--><\/p>\n<p><img decoding=\"async\" class=\"aligncenter size-full wp-image-62219\" src=\"https:\/\/nolabnoparty.com\/wp-content\/uploads\/2024\/05\/vsan-8-esa-on-minisforum-ms-01-02.jpg\" alt=\"\" width=\"287\" height=\"175\" title=\"\"><\/p>\n<p>&nbsp;<\/p>\n<h2>Prerequisites<\/h2>\n<p>For this deployment, three <strong>Minisforum MS-01<\/strong> with <strong>CPU i9-12900H<\/strong> and <strong>64GB RAM<\/strong> per node have been used.<\/p>\n<p>Before turning on vSAN 8 ESA, make sure your <strong>Physical adapters<\/strong> are properly connected.<\/p>\n<p><img decoding=\"async\" class=\"aligncenter size-large wp-image-62253\" src=\"https:\/\/nolabnoparty.com\/wp-content\/uploads\/2024\/05\/vsan-8-esa-on-minisforum-ms-01-03-600x235.jpg\" alt=\"\" width=\"600\" height=\"235\" title=\"\"><\/p>\n<p>In the Distributed Switch (or Virtual Switch) configure a <strong>dedicated vSAN portgroup<\/strong> to handle vSAN traffic. The vSAN traffic uses the <strong>10 Gbit\/s NIC<\/strong> provided by the Minisforum MS-01.<\/p>\n<p><img decoding=\"async\" class=\"aligncenter size-large wp-image-62223\" src=\"https:\/\/nolabnoparty.com\/wp-content\/uploads\/2024\/05\/vsan-8-esa-on-minisforum-ms-01-04-600x323.jpg\" alt=\"\" width=\"600\" height=\"323\" title=\"\"><\/p>\n<p>&nbsp;<\/p>\n<h2>Turn on vSAN 8 ESA on Minisforum MS-01<\/h2>\n<p>To configure vSAN 8 ESA, you need to first select the <strong>vSphere cluster<\/strong> then go to <strong>Configure &gt; vSAN &gt; Services<\/strong> section. Keep in mind if <strong>HA is enabled<\/strong>, vSAN cannot be turned on. Click <strong>Go to HA Settings<\/strong> link to disable the service.<\/p>\n<p><img decoding=\"async\" class=\"aligncenter size-large wp-image-62225\" src=\"https:\/\/nolabnoparty.com\/wp-content\/uploads\/2024\/05\/vsan-8-esa-on-minisforum-ms-01-05-600x311.jpg\" alt=\"\" width=\"600\" height=\"311\" title=\"\"><\/p>\n<p>When the HA service is disabled, vSAN can be turned on.<\/p>\n<p><img decoding=\"async\" class=\"aligncenter size-large wp-image-62227\" src=\"https:\/\/nolabnoparty.com\/wp-content\/uploads\/2024\/05\/vsan-8-esa-on-minisforum-ms-01-06-600x273.jpg\" alt=\"\" width=\"600\" height=\"273\" title=\"\"><\/p>\n<p>vSAN provides <strong>multiple deployment options<\/strong>:<\/p>\n<ul>\n<li><strong>vSAN HCI<\/strong> - this is the traditional deployment where compute and storage resources are aggregated in the same hosts that comprise the vSAN HCI cluster.<\/li>\n<li><strong>vSAN Compute Cluster<\/strong> - this topology (formerly referred to as <em>HCI Mesh<\/em>) provides <strong>compute resources only<\/strong> to vSAN Max clusters in the same data center and from remote vCenters.<\/li>\n<li><strong>vSAN Max<\/strong> - this topology provides <strong>storage resources only<\/strong> (not compute resources) to <strong>one or more vSphere clusters<\/strong> in the same data center and from remote vCenters.<\/li>\n<\/ul>\n<p>From <strong>Configure &gt; vSAN &gt; Services<\/strong> section, select <strong>vSAN HCI<\/strong> as configuration type and <strong>Single site vSAN cluster<\/strong> as topology (you need at least three nodes available for this configuration). Click <strong>Configure<\/strong>.<\/p>\n<p><img decoding=\"async\" class=\"aligncenter size-large wp-image-62229\" src=\"https:\/\/nolabnoparty.com\/wp-content\/uploads\/2024\/05\/vsan-8-esa-on-minisforum-ms-01-07-600x488.jpg\" alt=\"\" width=\"600\" height=\"488\" title=\"\"><\/p>\n<p>Enable the <strong>vSAN ESA<\/strong> switch to leverage vSAN 8 ESA capabilities and click <strong>Next<\/strong>.<\/p>\n<p><img decoding=\"async\" class=\"aligncenter size-large wp-image-62231\" src=\"https:\/\/nolabnoparty.com\/wp-content\/uploads\/2024\/05\/vsan-8-esa-on-minisforum-ms-01-08-600x365.jpg\" alt=\"\" width=\"600\" height=\"365\" title=\"\"><\/p>\n<p>If <a href=\"https:\/\/nolabnoparty.com\/en\/vsphere-vms-encryption-kms-server-installation-pt-1\/\">vSAN encryption<\/a> is not a requirement, click <strong>Next<\/strong>.<\/p>\n<p><img decoding=\"async\" class=\"aligncenter size-large wp-image-62233\" src=\"https:\/\/nolabnoparty.com\/wp-content\/uploads\/2024\/05\/vsan-8-esa-on-minisforum-ms-01-09-600x365.jpg\" alt=\"\" width=\"600\" height=\"365\" title=\"\"><\/p>\n<p>Detected NVMe disks are <strong>listed as incompatible<\/strong> since they are not in the HCL (this is a lab environment). <strong>Manually claim<\/strong> the disks. When NVMe disks have been claimed, click <strong>Next<\/strong>\u00a0to continue with the configuration.<\/p>\n<p><img decoding=\"async\" class=\"aligncenter size-large wp-image-62235\" src=\"https:\/\/nolabnoparty.com\/wp-content\/uploads\/2024\/05\/vsan-8-esa-on-minisforum-ms-01-10-600x365.jpg\" alt=\"\" width=\"600\" height=\"365\" title=\"\"><\/p>\n<p>If you don't need to define <strong>fault domains<\/strong>, click <strong>Next<\/strong>.<\/p>\n<p><img decoding=\"async\" class=\"aligncenter size-large wp-image-62237\" src=\"https:\/\/nolabnoparty.com\/wp-content\/uploads\/2024\/05\/vsan-8-esa-on-minisforum-ms-01-11-600x365.jpg\" alt=\"\" width=\"600\" height=\"365\" title=\"\"><\/p>\n<p>Click <strong>Finish<\/strong> to turn on vSAN 8 ESA.<\/p>\n<p><img decoding=\"async\" class=\"aligncenter size-large wp-image-62239\" src=\"https:\/\/nolabnoparty.com\/wp-content\/uploads\/2024\/05\/vsan-8-esa-on-minisforum-ms-01-12-600x365.jpg\" alt=\"\" width=\"600\" height=\"365\" title=\"\"><\/p>\n<p>The cluster is being created.<\/p>\n<p><img decoding=\"async\" class=\"aligncenter size-large wp-image-62241\" src=\"https:\/\/nolabnoparty.com\/wp-content\/uploads\/2024\/05\/vsan-8-esa-on-minisforum-ms-01-13-600x488.jpg\" alt=\"\" width=\"600\" height=\"488\" title=\"\"><\/p>\n<p>You can check the process status in the <strong>Recent Tasks<\/strong> section.<\/p>\n<p><img decoding=\"async\" class=\"aligncenter size-large wp-image-62243\" src=\"https:\/\/nolabnoparty.com\/wp-content\/uploads\/2024\/05\/vsan-8-esa-on-minisforum-ms-01-14-600x238.jpg\" alt=\"\" width=\"600\" height=\"238\" title=\"\"><\/p>\n<p>After a few minutes, the vSAN is <strong>configured successfully<\/strong>.<\/p>\n<p><img decoding=\"async\" class=\"aligncenter size-large wp-image-62245\" src=\"https:\/\/nolabnoparty.com\/wp-content\/uploads\/2024\/05\/vsan-8-esa-on-minisforum-ms-01-15-600x224.jpg\" alt=\"\" width=\"600\" height=\"224\" title=\"\"><\/p>\n<p>Also the <strong>Skyline Health<\/strong> is almost perfect.<\/p>\n<p><img decoding=\"async\" class=\"aligncenter size-large wp-image-62247\" src=\"https:\/\/nolabnoparty.com\/wp-content\/uploads\/2024\/05\/vsan-8-esa-on-minisforum-ms-01-16-600x275.jpg\" alt=\"\" width=\"600\" height=\"275\" title=\"\"><\/p>\n<p>There is only a warning related to <strong>unsupported NVMe disks<\/strong>, but that\u2019s to be expected. You can safely click <strong>Silence Alert<\/strong>.<\/p>\n<p><img decoding=\"async\" class=\"aligncenter size-large wp-image-62249\" src=\"https:\/\/nolabnoparty.com\/wp-content\/uploads\/2024\/05\/vsan-8-esa-on-minisforum-ms-01-17-600x380.jpg\" alt=\"\" width=\"600\" height=\"380\" title=\"\"><\/p>\n<p>vSAN 8 ESA is now configured in the VMware environment. Remember to <strong>re-enable the HA service<\/strong>.<\/p>\n<p><img decoding=\"async\" title=\"signature\" src=\"https:\/\/nolabnoparty.com\/wp-content\/uploads\/images\/firma.jpg\" alt=\"signature\" \/><\/p>\n","protected":false},"excerpt":{"rendered":"<p>To install the new vSAN 8 ESA (Express Storage Architecture) on Minisforum MS-01, it is required to have NVMe disks only as internal storage in the hosts. Checking the hardware compatibility of Minisforum MS-01 used as hypervisor, prerequisites are not 100% met (it complains about NVMe disks) but enough to finalize the installation.<\/p>\n","protected":false},"author":3,"featured_media":62217,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"rop_custom_images_group":[],"rop_custom_messages_group":[],"rop_publish_now":"initial","rop_publish_now_accounts":{"linkedin_93tdZWzMZc_93tdZWzMZc":"","facebook_2879994398731222_17841400390232720":"","twitter_113568041_113568041":"","mastodon_115463926174894442_115463926174894442":""},"rop_publish_now_history":[],"rop_publish_now_status":"pending","footnotes":""},"categories":[903,1853],"tags":[2847,2848,2849,2850,700],"class_list":["post-62212","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-vmware-en","category-vsan-en","tag-esa","tag-minisforum","tag-ms-01","tag-vsan-8","tag-vsphere-en","has_thumb"],"_links":{"self":[{"href":"https:\/\/nolabnoparty.com\/en\/wp-json\/wp\/v2\/posts\/62212","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/nolabnoparty.com\/en\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/nolabnoparty.com\/en\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/nolabnoparty.com\/en\/wp-json\/wp\/v2\/users\/3"}],"replies":[{"embeddable":true,"href":"https:\/\/nolabnoparty.com\/en\/wp-json\/wp\/v2\/comments?post=62212"}],"version-history":[{"count":0,"href":"https:\/\/nolabnoparty.com\/en\/wp-json\/wp\/v2\/posts\/62212\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/nolabnoparty.com\/en\/wp-json\/wp\/v2\/media\/62217"}],"wp:attachment":[{"href":"https:\/\/nolabnoparty.com\/en\/wp-json\/wp\/v2\/media?parent=62212"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/nolabnoparty.com\/en\/wp-json\/wp\/v2\/categories?post=62212"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/nolabnoparty.com\/en\/wp-json\/wp\/v2\/tags?post=62212"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}